Specifications
Document Download | ANL-8010 2GHz GWR radar level Gauges Overview |
MKT-24 ANL-8010-8010S 1GHz Guided Wave Radar_EN[DY0217] |
ANL-8010P | Rod | Cable | Coax |
---|---|---|---|
Max. measuring range | Max. 10m / Level or Level & Interface | Max. 45m / Level or Level & Interface | DK >1.4 Max. 6m / Level or Level & Interface |
DK value | DK >1.4 | DK >1.6 @ ≤30m, DK >2.0 @ >30m | DK >1.2 |
Probe | Ø 8 / Ø 10 (default) / Ø 12mm | Ø 2 / Ø 4 / Ø 6mm (default) | Ø 22 / Ø 32(default) / Ø 42mm |
Process fitting / Material wetted parts |
Thread G¾, G1, G1½, NPT/ Flanges >= DN25 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Thread G¾, G1, G1½, NPT / Flanges >= DN50 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Thread G¾, G1, G1½, NPT /Flanges >= DN50 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Ambient temperature | -40 … +85 °C / -60 … +105 °C (cool version) | ||
Process temperature | -60°C … +200°C / PEEK , -40°C … +200°C / PTFE, -195°C … +260°C / PFA | ||
Max. process pressure | -1 … 4MPa | -1 … 4MPa | -1 … 4MPa |
Measuring accuracy |
liquid level: ±2 mm medium level ,Interface: ±5 mm |
liquid level: ±2 mm@<=15M, ±6 mm@>15M medium level, Interface: ±8 mm |
liquid level: ±1 mm medium level, Interface: ±5 mm |
Signal output | 4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire | ||
Variables influencing meas. accuracy |
Specifications for the digital measured value: Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm Specifications apply also to the current output Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15% Deviation in the current output due to digital/analogue conversion Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA |
||
Indication/Adjustment |
1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 2. (APP) Radar MobileManager via BT wireless connection 3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required) |
||
Power supply | 14.5V ~ 40 VDC / Load resistor > 600Ω | ||
Wireless communication | Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m | ||
Approvals | Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67 | ||
Housing | Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68 | ||
Applications | Storage silos, storage tanks, liquids with smooth surface | Storage tanks, liquids with agitated surface, high storage silos, silos with product movement | Storage tanks, liquids with low dielectric constant, vessel with installations |
ANL-8010P- high-temperature | Rod | Cable | Coax |
---|---|---|---|
Max. measuring range | Max. 10m / Level or Level & Interface | Max. 45m / Level or Level & Interface | DK >1.4 Max. 6m / Level or Level & Interface |
DK value | DK >1.4 | DK >1.6 @ ≤30m, DK >2.0 @ >30m | DK >1.2 |
Probe | Ø 8 / Ø 10 (default) / Ø 12mm | Ø 2 / Ø 4 / Ø 6mm (default) | Ø 22 / Ø 32(default) / Ø 42mm |
Process fitting / Material wetted parts |
Thread G¾, G1, G1½, NPT/ Flanges >= DN25 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Thread G¾, G1, G1½, NPT / Flanges >= DN50 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Thread G¾, G1, G1½, NPT /Flanges >= DN50 304L/316L/Alloy C, PEEK / PTFE (default) / PFA |
Ambient temperature | --40 … +85 °C / -60 … +105 °C (cool version) | ||
Process temperature | -60°C … +300°C / PEEK , -40°C … +300°C / PTFE , -195°C … +360°C / PFA | ||
Max. process pressure | -1 … 4MPa | -1 … 4MPa | -1 … 4MPa |
Measuring accuracy |
liquid level: ±2 mm medium level ,Interface: ±5 mm |
liquid level: ±2 mm@<=15M, ±6 mm@>15M medium level, Interface: ±8 mm |
liquid level: ±1 mm medium level, Interface: ±5 mm |
Signal output | 4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire | ||
Variables influencing meas. accuracy |
Specifications for the digital measured value: Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm Specifications apply also to the current output Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15% Deviation in the current output due to digital/analogue conversion Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA |
||
Indication/Adjustment |
1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 2. (APP) Radar MobileManager via BT wireless connection 3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required) |
||
Power supply | 14.5V ~ 40 VDC / Load resistor > 600Ω | ||
Wireless communication | Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m | ||
Approvals | Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67 | ||
Housing | Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68 | ||
Applications | Storage silos, storage tanks, liquids with smooth surface | Storage tanks, liquids with agitated surface, high storage silos, silos with product movement | Storage tanks, liquids with low dielectric constant, vessel with installations |
ANL-8010 2GHz GWR radar level Gauges Overview
结构规格 Series |
8010 Regular version |
8010S HTversion |
8010H HTHP version |
8010P Remote connection |
8010PH Remote connection |
---|---|---|---|---|---|
Exia/Exd Single/Double Chamber |
Single/Double | Single/Double | Single/Double | Single/Double | Single/Double |
Cable probe/SS304/SS316 | 2/4/6mm(default) | 2/4/6mm(default) | 4mm/6mm(default) | 4mm/6mm(default) | 6mm(default) |
Rod probe/SS304/SS316 | 6/8/10(default)/12mm | 6/8/10(default)/12mm | 8mm/10mm/16mm | 8mm/10mm/16mm | 8mm/10mm/16mm |
Coax probe/SS304/SS316 | 22/25/32/42mm | 22/25/32/42mm | 22/25/32/42mm | 22/25/32/42mm | 22/25/32/42mm |
Max.process pressure | 4MPa | 4MPa | <=4MPa | <=4MPa | <=4MPa |
Level/interface | Level or Level/Interface | Level or Level/Interface | Level or Level/Interface | Level or Level/Interface | Level or Level/Interface |
Process fittings:Pipe thread | G¾,G1,G1½//NPT | G¾,G1,G1½//NPT | G¾,G1,G1½,G3//NPT | G¾,G1,G1½//NPT | G¾,G1,G1½//NPT |
Self-struc.process Temp.[1] | -60℃~+200℃/PEEK -40℃~+200℃/PTFE -196℃~+260℃/PFA |
-60℃~+300℃/PEEK -40℃~+300℃/PTFE -196℃~+360℃/PFA |
-196℃~+450℃ | -60℃~+200℃/PEEK -40℃~+200℃/PTFE -196℃~+360℃/PFA |
-196℃~+850℃ |
Config Min.flange size | DN32 | DN32 | DN32 | DN32 | DN32 |
Process seal on the instrument side(cable/rod lead through) |
PTFE/PEEK/PFA | PTFE/PEEK/PFA | Ceramics | PTFE/PEEK/PFA | Zirconia Ceramic |
O-ring list
Code | Global Name | CN Name | CN Brand | Shore A | Temperature |
---|---|---|---|---|---|
N | None | ||||
K |
Kalrez6375 Perfluoroelastomer |
全氟醚橡胶 |
TRUFLOUREZ-T23 |
75 | -15℃~230℃ |
TRUFLOUREZ-T80 | 70 | -15℃~310℃ | |||
TRUFLOUREZ-T32 | 75 | -15℃~325℃ | |||
TRUFLOUREZ-T26 | 70 | -15℃~260℃ | |||
TRUFLOUREZ-T30 | 75 | -15℃~300℃ | |||
TRUFLOUREZ-T95 | 60 | -15℃~300℃ | |||
E |
EPDM |
三元乙丙橡胶 |
TRUFLOUREZ-EPDM | SA40-90 | -5℃~300℃ |
V |
Viton Fluoroelasromer |
氟橡胶 |
Ref.to Viton O-ring list | ||
B |
NBR |
丁腈橡胶 |
TRUFLOUREZ-NBR | SA50-90 | -40℃~120℃ |
L |
Low-Temperature Viton Fluoroelasromer |
低温氟橡胶 |
Ref.to Viton O-ring list | ||
F |
FVMQ |
氟硅橡胶 |
TRUFLOUREZ-FVMQ | SA45-80 | -60℃~230℃ |
P | PTFE seal | 四氟弹簧密封圈 | FMH-PTFE o-ring | SB-200 | -200℃~300℃ |
Product dimensions
Adapters / Accessories
DTM Adapter for ANL-8010
Remote programmer cum Indicator Adapters
Remote indicator via Bluetooth communication
ANL-9080 radar level transmitters (with Bluetooth function) can be connected to mobile phone through Bluetooth wireless system. The mobile phone needs to install the RadarMobileManager APP. This is a free registered APP (Android and IOS etc.) software, which can be downloaded and installed directly in major APP Stores, or please contact the relevant product suppliers.
Remote indicator with HART compatible (RDM-25)
Remote indicator via Serial communication (LRD-21)
Indication/Adjustment LOI Adapter