ANL-8010H (high-temperature & high-pressure version )Guided Wave Radar Level and interface transmitters

This product can measure the level and interface of liquids and solids in various extreme conditions. It supports mobile phone to adjust the user interface or remote parameter setting. It is not affected by density fluctuations, steam, pressure, and temperature changes, or the build-up on the probe or vessel wall. It uses innovative multi-echo tracking technology, built-in pre-calibration data, and can measure reliably under fluctuating liquid levels and foams. It has one digital and two current output options, self-monitoring meets the NE43/NE107 standard, real-time measurement with overvoltage protection, and supports the connection of tank tables for distributed display and debugging.

Application
■ Typical process properties in liquids, solids, hygienic and extreme condition applications, even in strong construction with dual seal to ensure its integrity in applications including options for aggressive such as ammonia etc.
■ The intelligent software guarantees high measurement certainty and a well monitored probe. An ideal application is level measurement in a bypass tube or standpipe, because even products with a dielectric constant below 1.2 can be reliably measured.
■ The ANL-8010H features advanced measurement techniques that provide a unique solution to the saturated steam applications, such as high temperature high pressure water used in power generation.
■ The ANL-8010H GWR transmitter is capable of effectively measuring both an upper liquid level and an interface liquid level. It is typically required that the upper liquid has a dielectric constant less than 10, and the lower liquid has a dielectric constant greater than 15. A typical interface application would be oil over water, with the upper layer of oil being non-conductive (DK≈2.0), and the lower layer of water being very conductive (DK≈80).
■ Different probes are available, field replaceable and adjustable probes.

To order or inquire, please contact us


Quantity:
Price: 0.00 USD

Characteristics

■ Level, Level/interface measurement in liquids, solids, hygienic and extreme conditions.
■ The user interface of the product can be adjusted through mobile phone or remote parameter setting can be supported without going to on-site.
■ Density fluctuations, steam generation or strong pressure and temperature fluctuations do not influence the measuring result.
■ Build-up on the probe or the vessel wall do not influence the measurement
■ Product adopts innovative multi-echo tracking technology, built-in storage of factory pre-calibration data, reliable measurement under fluctuating liquid levels and foams.
■ One digital and 2 current output options available, self-monitoring meets theNE43/NE107 standards.
■ Real-time measurements with inside overvoltage protection.
■ It supports the connection of tank tables to achieve distributed display and debugging.

Gas-phase compensation

Gas phase compensation with reference signal (ANL-8010H-GP)

In the high-pressure application, the propagation speed of GWR signals is reduced in the steam (polar media) above the liquid to be measured. As a result, the Level signal indicates the level too low.

As an option ANL-8010H-GP version is available in a version with automatic gas phase correction, which corrects this error. (option Gas Phase Compensation G= 300mm/550mm). This version of the ANL-8010H-GP generates a reference reflection in the distance G from the flange by a diameter step of the probe rod.

NOTE: The reference reflection must be at least 150 mm above the highest level. By means of the shift of the reference reflection the actual propagation speed is measured and the level value will be automatically corrected. with reference reflection can be installed in any tank (free in the tank or into a bypass). Coax probes are completely mounted and adjusted ex works. Rod probes are only recommended if the installation of a coax probe is not possible (e.g. if the bypass diameter is too small).
Rod probes with reference reflection are only suited for mounting in stilling wells and side gauges (bypasses).
Level measurements with high pressure for measuring ranges up to a few meters in polar media with a dielectric constant DK > 7 (e.g. water or ammonia), which would cause a high measuring error without the compensation.

Specifications

Document Download ANL-8010 2GHz GWR radar level Gauges Overview
MKT-24 ANL-8010H 1GHz HTHP GWR_EN[DY0316]

 

  ANL-8010H-rod Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010H_cable Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010H_coaxial Liquid level measurement and liquid level/media interface guided wave radar transducer
ANL-8010H - x Rod Cable Coax
Max. measuring range Max. 6m / Level or Level & Interface  Max. 45m / Level or Level & Interface  Max. 6m / Level or Level & Interface
DK value  DK >1.4  DK >1.6 @ ≤15m, DK >2.0 @ >15m  DK >1.2
Probe  Ø 8 / Ø 10 (default) / Ø 12mm  Ø 2 / Ø 4 / Ø 6mm (default)  Ø 22 / Ø 32(default) / Ø 42mm
Process fitting / Material wetted parts Thread G1, G1½, NPT/ Flanges >= DN50, 304L/316L/Alloy C (options), Borosilicate glass, graphite
Dual seal and meet the ASNI/ISA 12.27.01 specifications
Ambient temperature  -40 … +85 °C / -60 … +105 °C (cool version)
Process temperature -196°C … +450°C
Max. process pressure  -1 … 4MPa  -1 … 4MPa  -1 … 4MPa
Measuring accuracy

level: ±2 mm
Interface: ±5 mm

level: ±2 mm@<=15M, ±6 mm@>15M
Interface: ±8 mm

level: ±1 mm
Interface: ±5 mm

Signal output  4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire
Variables influencing meas. accuracy

Specifications for the digital measured value
Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm
Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm
Specifications apply also to the current output
Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15%
Deviation in the current output due to digital/analogue conversion
Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA
Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA

Indication/Adjustment

 1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C.
    or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option)
    or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system)
2. (APP) Radar MobileManager via BT wireless connection
3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required)

Power supply  14.5V ~ 40 VDC / Load resistor > 600Ω
Wireless communication  Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m
Approvals  Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67
Housing Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68
Applications liquids, solids, hygienic and extreme condition high-temperature and high-pressure applications

ANL-8010 2GHz GWR radar level Gauges Overview

结构规格
Series
8010
Regular version
8010S
HTversion
8010H
HTHP version
8010P
Remote connection
8010PH
Remote connection
Exia/Exd
Single/Double Chamber
Single/Double Single/Double Single/Double Single/Double Single/Double
Cable probe/SS304/SS316 2/4/6mm(default) 2/4/6mm(default) 4mm/6mm(default) 4mm/6mm(default) 6mm(default)
Rod probe/SS304/SS316 6/8/10(default)/12mm 6/8/10(default)/12mm 8mm/10mm/16mm 8mm/10mm/16mm 8mm/10mm/16mm
Coax probe/SS304/SS316 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm
Max.process pressure 4MPa 4MPa <=4MPa <=4MPa <=4MPa
Level/interface Level or Level/Interface Level or Level/Interface Level or Level/Interface Level or Level/Interface Level or Level/Interface
Process fittings:Pipe thread G¾,G1,G1½//NPT G¾,G1,G1½//NPT G¾,G1,G1½,G3//NPT G¾,G1,G1½//NPT G¾,G1,G1½//NPT
Self-struc.process Temp.[1] -60℃~+200℃/PEEK
-40℃~+200℃/PTFE
-196℃~+260℃/PFA
-60℃~+300℃/PEEK
-40℃~+300℃/PTFE
-196℃~+360℃/PFA
-196℃~+450℃ -60℃~+200℃/PEEK
-40℃~+200℃/PTFE
-196℃~+360℃/PFA
-196℃~+850℃
Config Min.flange size DN32 DN32 DN32 DN32 DN32
Process seal on the instrument
side(cable/rod lead through)
PTFE/PEEK/PFA PTFE/PEEK/PFA Ceramics PTFE/PEEK/PFA Zirconia Ceramic

O-ring list

Code Global Name CN Name CN Brand Shore A Temperature
N None  
K

Kalrez6375 Perfluoroelastomer

全氟醚橡胶

TRUFLOUREZ-T23

75 -15℃~230℃
TRUFLOUREZ-T80 70 -15℃~310℃
TRUFLOUREZ-T32 75 -15℃~325℃
TRUFLOUREZ-T26 70 -15℃~260℃
TRUFLOUREZ-T30 75 -15℃~300℃
TRUFLOUREZ-T95 60 -15℃~300℃
E

EPDM

三元乙丙橡胶

TRUFLOUREZ-EPDM SA40-90 -5℃~300℃
V

Viton Fluoroelasromer

氟橡胶

Ref.to Viton O-ring list
B

NBR

丁腈橡胶

TRUFLOUREZ-NBR SA50-90 -40℃~120℃
L

Low-Temperature Viton Fluoroelasromer

低温氟橡胶

Ref.to Viton O-ring list
F

FVMQ

氟硅橡胶

TRUFLOUREZ-FVMQ SA45-80 -60℃~230℃
P PTFE seal 四氟弹簧密封圈 FMH-PTFE o-ring SB-200 -200℃~300℃

Dimensions

ANL-8010H G¾ G1 G1½ Serials standard specification

ANL-8010H Dimensions


Aluminum housing

ANL-8010 can be directly connected and debugged with a computer equipped with PACTware/DTM software through the AiW-305-USB converter.

DTM Adapter for ANL-8010

Remote programmer cum Indicator Adapters

Remote indicator via Bluetooth communication
ANL-9080 radar level transmitters (with Bluetooth function) can be connected to mobile phone through Bluetooth wireless system. The mobile phone needs to install the RadarMobileManager APP. This is a free registered APP (Android and IOS etc.) software, which can be downloaded and installed directly in major APP Stores, or please contact the relevant product suppliers.

Remote indicator with HART compatible (RDM-25)

Remote indicator via Serial communication (LRD-21)

Indication/Adjustment LOI Adapter


Stainless steel housing


Plastic housing

 

 

Application installation

© Chinasimba 2004 - 2024