ANL-8010P Serials Guided Wave Radar Level and interface transmitters

The ANL-8010P anti-nuclear radiation radar level gauge is a specially designed liquid level measurement instrument, suitable for the measurement of liquid tanks that need to resist strong radiation and high temperatures. It adopts a split-type radar design and enables separate on-site installation. The maximum custom length of the anti-radiation N-type coaxial cable is 120 meters. In a nuclear radiation environment, this radar level gauge has an excellent anti-radiation ability, can effectively withstand the influence of nuclear radiation, and ensure the accuracy and stability of liquid level measurement. Its high-temperature resistance characteristic enables it to operate normally in high-temperature environments and is applicable to scenarios such as nuclear power generation and nuclear waste treatment. Its split design facilitates maintenance and component replacement, enhancing the reliability and service life of the equipment.


Quantity:
Price: 0.00 USD

Specifications

Document Download ANL-8010 2GHz GWR radar level Gauges Overview
MKT-24 ANL-8010-8010S 1GHz Guided Wave Radar_EN[DY0217]

 

  ANL-8010-rod Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010_cable Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010_coaxial Liquid level measurement and liquid level/media interface guided wave radar transducer
ANL-8010P Rod Cable Coax
Max. measuring range Max. 10m / Level or Level & Interface  Max. 45m / Level or Level & Interface DK >1.4 Max. 6m / Level or Level & Interface
DK value  DK >1.4  DK >1.6 @ ≤30m, DK >2.0 @ >30m  DK >1.2
Probe  Ø 8 / Ø 10 (default) / Ø 12mm  Ø 2 / Ø 4 / Ø 6mm (default)  Ø 22 / Ø 32(default) / Ø 42mm
Process fitting / Material wetted parts

 Thread G¾, G1, G1½, NPT/ Flanges >= DN25

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

 Thread G¾, G1, G1½, NPT / Flanges >= DN50

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

 Thread G¾, G1, G1½, NPT /Flanges >= DN50

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

Ambient temperature  -40 … +85 °C / -60 … +105 °C (cool version)
Process temperature  -60°C … +200°C / PEEK , -40°C … +200°C / PTFE, -195°C … +260°C / PFA
Max. process pressure  -1 … 4MPa  -1 … 4MPa  -1 … 4MPa
Measuring accuracy

 liquid level: ±2 mm 

medium level ,Interface: ±5 mm

liquid level: ±2 mm@<=15M, ±6 mm@>15M

medium level,  Interface: ±8 mm

liquid level: ±1 mm 

medium level, Interface: ±5 mm

Signal output  4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire
Variables influencing meas. accuracy

 Specifications for the digital measured value:

 Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm

 Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm 

Specifications apply also to the current output

 Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15%

 Deviation in the current output due to digital/analogue conversion

 Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA 

Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA

Indication/Adjustment

 1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. 

or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) 

or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 

2. (APP) Radar MobileManager via BT wireless connection

 3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required)

Power supply  14.5V ~ 40 VDC / Load resistor > 600Ω
Wireless communication  Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m
Approvals  Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67
Housing  Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68
Applications  Storage silos, storage tanks, liquids with smooth surface  Storage tanks, liquids with agitated surface, high storage silos, silos with product movement  Storage tanks, liquids with low dielectric constant, vessel with installations
  ANL-8010S_pole Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010S_cable Liquid level measurement and liquid level/media interface guided wave radar transducer ANL-8010S_coaxial Liquid level measurement and liquid level/media interface guided wave radar transducer
ANL-8010P- high-temperature Rod Cable Coax
Max. measuring range Max. 10m / Level or Level & Interface  Max. 45m / Level or Level & Interface DK >1.4 Max. 6m / Level or Level & Interface
DK value  DK >1.4  DK >1.6 @ ≤30m, DK >2.0 @ >30m  DK >1.2
Probe  Ø 8 / Ø 10 (default) / Ø 12mm  Ø 2 / Ø 4 / Ø 6mm (default)  Ø 22 / Ø 32(default) / Ø 42mm
Process fitting / Material wetted parts

 Thread G¾, G1, G1½, NPT/ Flanges >= DN25

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

 Thread G¾, G1, G1½, NPT / Flanges >= DN50

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

 Thread G¾, G1, G1½, NPT /Flanges >= DN50

304L/316L/Alloy C, PEEK / PTFE (default) / PFA

Ambient temperature  --40 … +85 °C / -60 … +105 °C (cool version)
Process temperature  -60°C … +300°C / PEEK , -40°C … +300°C / PTFE , -195°C … +360°C / PFA
Max. process pressure  -1 … 4MPa  -1 … 4MPa  -1 … 4MPa
Measuring accuracy

 liquid level: ±2 mm 

medium level ,Interface: ±5 mm

liquid level: ±2 mm@<=15M, ±6 mm@>15M

medium level,  Interface: ±8 mm

liquid level: ±1 mm 

medium level, Interface: ±5 mm

Signal output  4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire
Variables influencing meas. accuracy

 Specifications for the digital measured value:

 Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm

 Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm 

Specifications apply also to the current output

 Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15%

 Deviation in the current output due to digital/analogue conversion

 Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA 

Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA

Indication/Adjustment

 1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. 

or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) 

or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 

2. (APP) Radar MobileManager via BT wireless connection

 3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required)

Power supply  14.5V ~ 40 VDC / Load resistor > 600Ω
Wireless communication  Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m
Approvals  Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67
Housing  Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68
Applications  Storage silos, storage tanks, liquids with smooth surface  Storage tanks, liquids with agitated surface, high storage silos, silos with product movement  Storage tanks, liquids with low dielectric constant, vessel with installations

ANL-8010 2GHz GWR radar level Gauges Overview

结构规格
Series
8010
Regular version
8010S
HTversion
8010H
HTHP version
8010P
Remote connection
8010PH
Remote connection
Exia/Exd
Single/Double Chamber
Single/Double Single/Double Single/Double Single/Double Single/Double
Cable probe/SS304/SS316 2/4/6mm(default) 2/4/6mm(default) 4mm/6mm(default) 4mm/6mm(default) 6mm(default)
Rod probe/SS304/SS316 6/8/10(default)/12mm 6/8/10(default)/12mm 8mm/10mm/16mm 8mm/10mm/16mm 8mm/10mm/16mm
Coax probe/SS304/SS316 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm 22/25/32/42mm
Max.process pressure 4MPa 4MPa <=4MPa <=4MPa <=4MPa
Level/interface Level or Level/Interface Level or Level/Interface Level or Level/Interface Level or Level/Interface Level or Level/Interface
Process fittings:Pipe thread G¾,G1,G1½//NPT G¾,G1,G1½//NPT G¾,G1,G1½,G3//NPT G¾,G1,G1½//NPT G¾,G1,G1½//NPT
Self-struc.process Temp.[1] -60℃~+200℃/PEEK
-40℃~+200℃/PTFE
-196℃~+260℃/PFA
-60℃~+300℃/PEEK
-40℃~+300℃/PTFE
-196℃~+360℃/PFA
-196℃~+450℃ -60℃~+200℃/PEEK
-40℃~+200℃/PTFE
-196℃~+360℃/PFA
-196℃~+850℃
Config Min.flange size DN32 DN32 DN32 DN32 DN32
Process seal on the instrument
side(cable/rod lead through)
PTFE/PEEK/PFA PTFE/PEEK/PFA Ceramics PTFE/PEEK/PFA Zirconia Ceramic

O-ring list

Code Global Name CN Name CN Brand Shore A Temperature
N None  
K

Kalrez6375 Perfluoroelastomer

全氟醚橡胶

TRUFLOUREZ-T23

75 -15℃~230℃
TRUFLOUREZ-T80 70 -15℃~310℃
TRUFLOUREZ-T32 75 -15℃~325℃
TRUFLOUREZ-T26 70 -15℃~260℃
TRUFLOUREZ-T30 75 -15℃~300℃
TRUFLOUREZ-T95 60 -15℃~300℃
E

EPDM

三元乙丙橡胶

TRUFLOUREZ-EPDM SA40-90 -5℃~300℃
V

Viton Fluoroelasromer

氟橡胶

Ref.to Viton O-ring list
B

NBR

丁腈橡胶

TRUFLOUREZ-NBR SA50-90 -40℃~120℃
L

Low-Temperature Viton Fluoroelasromer

低温氟橡胶

Ref.to Viton O-ring list
F

FVMQ

氟硅橡胶

TRUFLOUREZ-FVMQ SA45-80 -60℃~230℃
P PTFE seal 四氟弹簧密封圈 FMH-PTFE o-ring SB-200 -200℃~300℃

Product dimensions

Adapters / Accessories

DTM Adapter for ANL-8010

Remote programmer cum Indicator Adapters

Remote indicator via Bluetooth communication
ANL-9080 radar level transmitters (with Bluetooth function) can be connected to mobile phone through Bluetooth wireless system. The mobile phone needs to install the RadarMobileManager APP. This is a free registered APP (Android and IOS etc.) software, which can be downloaded and installed directly in major APP Stores, or please contact the relevant product suppliers.

Remote indicator with HART compatible (RDM-25)

Remote indicator via Serial communication (LRD-21)

Indication/Adjustment LOI Adapter

© Chinasimba 2004 - 2024
闽公网安备35010502000147号