ANL/AiW-4120MC Non-contact Smart Radar Level Gauges

Aiw4120MC model frequency: using 120GHz FMCW radar system. Suitable for measuring liquids and bulk solids in small storage tanks, as well as applications in reactive and corrosive environments in the chemical industry. The Aiw4120MC radar level gauge is suitable for various measurement scenarios of liquid and solid materials, including but not limited to: liquid level monitoring in water/sewage treatment processes; Measurement of liquid and material levels in reaction vessels and storage tanks in the chemical industry; Applications that require continuous level monitoring in corrosive environments.

To order or inquire, please contact us


Quantity:
Price: 0.00 USD

Characteristics

■ 120GHz Frequency FMCW radar system.
■ Measuring application in liquids, solids.
■ Suitable for water/sewage treatment applications.

Specifications

Document Download

AiW-4120MPMC_120GHz Operation_Manual_DY0723

AiW-4120_catalog_EN[DY0511]

ANL/AiW-4120MC Lens material POM Lens material PTFE Note
Max. measuring range 10M/18M/20M/30M/40M 40M only for HART/IO-Link/APL version
Near blind spot < 100mm from the Antenna down surface
Tx/Rx frequency Tx/Rx frequency 120 to 125GHz Dynamic FM Sweep Bandwidth 1~5GHz
(The adjustment FM range can be customized according to the ISM requirements of the customer’s region)
Meas. Principle FMCW Radar System, TX power -3dBm (not included antennas), RX Input compression point -20dBm & Gain 10dB (not included antennas)
Lens Antenna Medium POM Φ30mm PTFE Φ30mm Material exposed to tank atmosphere
Antenna beam / Gain Beam angle 6°/ Gain 25.8dB Beam angle 4.5°/ Gain 31.7dB
Meas. Resolution 0.1mm (<10m range) Depends on the bandwidth and range
Meas. Accuracy ±1mm (<10m range) / ±2mm (18m/20m range) / ±4mm (30m/40m range)
Ambient temperature -40 … +85 °C -40 … +85 °C
Process temperature -40°C … +120°C -40°C … +120°C
Process pressure -0.1 ~ +2.5MPa -0.1 ~ +2.3MPa
Process connection Thread G1-1/2 NPT
Signal output  4-20 mA (regular), or/ 4-20 mA/HART7, or/ (RS-485) Modbus, or/ IO-Link, or/ Ethernet-APL (option issue)
Variables influencing meas. accuracy

 Specifications for the digital measured value:

       Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm

       Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm 

Specifications apply also to the current output

       Temperature drift - Current output:  ±0.01%/10K relating to the 16.7 mA span or max. ±0.15%

 Deviation in the current output due to digital/analogue conversion

       Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA 

       Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA

Indication/Adjustment (LOI)

 1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. 

       or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) 

       or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 

2. (APP) Radar MobileManager via BT wireless connection

3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required)

Indication/Adjustment (LOI) (APP) RadarMobileManager via BT wireless connection
Meas. output update rate < 3s. (Run-up time to get first Reading: <5s forRS485; <45s for mA loop) @UB=16VDC
Power supply 16V … 40 VDC / Load resistor > 500Ω (for mA version), 12V… 36VDC (for RS485 version)
Wireless communication Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m
Approvals  CLEx/CNEx: Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67
Housing  Plastic POM or PTFE, IP67 / IP68
Applications Liquids, solids, and corrosive environment applications

Summary of the ANL/AiW-4120 radar level transmitter models parameter table

Dimensions

The Radar Antenna Specification of the AiW/ANL-4120MC

© Chinasimba 2004 - 2024
闽公网安备35010502000147号