ANL-9081 80GHz Guided Pipe Radar Level Transmitter

The ANL-9081 80GHz FMCW radar is straight pipe level measurement radar with a low loss mode , designed to measure the level of liquid or powder in straight pipes (internal diameter > 50mm); it can measure up to 40m in length, allowing slight curvature (<0.3 degrees, about 0.1m off axis for a 20m long pipe), for rough or sticky pipe walls. It is also capable of measuring in the case of material hanging (as long as the wall thickness of the material does not exceed 1/3 of the inner diameter of the pipe).

The ANL9081 low loss mode radar signal is transmitted using TE01 technology, which allows radar waves to penetrate quartz glass (or PTFE/PEEK) blind flanges with very low loss, but also completely penetrates saturated vapour media and avoids reflections from rusting and deposits on the inner wall of the duct. Effective and cost effective for level measurement in corrosion protection and high temperature and high pressure environments, ideal for use on bypass tubes, replacing industrial applications where Guided Wave Radar is not suitable.

Application:High temperature and pressure, Bypass, Petrochemical, Medical, Floating top tanks, Marine, Food and Grain

To order or inquire, please contact us


Quantity:
Price: 0.00 USD

Benifits

  • Level measurement in long straight pipes
  • High temperature and pressure on Bypass tube, Level measurement
  • Zero dead band, high penetration and accuracy

Specifications

Radar Frequency 76.2 to 80.2GHz dynamic FM sweep bandwidth 4GHz (On demand adjustment on the FM sweep bandwidth is available to comply with ISM requirements)
Measuring range 10.0M / 40.0M
Dead Band 0mm
Measuring principle FMCW Radar TE01 Mode
Resolution 0.1mm (10M for range) / 0.5mm (40M for range)
Accuracy ±1mm (10m for range) / ±5mm (40m for range)
Antenna Material PEEK material, Lensed Antenna
Antenna Beam Modular lens RF beam 12° @ (Class 1 lens antenna)
Signal Output 4-20mA, HART5(standard) / HART7
Power Supply 16V~36VDC / 2-wire
Process connection DN50 Flange
Process temperature ‐40 ~ 150℃/‐40 ~600℃ (Extra cooling fins are required )
Ambient temperature ‐40 ~ 85℃,≤95%RH
Process Pressure ‐1 ~ 4MPa /‐4~32MPa(Extra reinforced flange members are required)
Local Configurable PC desktop software(Radar PCManger) / 4 on panel push buttons/ Smartphone app and Wechat Mini-program (RadarMobileManger) / Vessel Side Meter
WIFI Connection Bluetooth / LoRa / IOT
Comm.Protocol HART / MODBUS / PROFIBUS (Optional)
Fail-safe 22mA / 4mA/20.5mA (configurable)
Display 160x80 dot matrix black and white monochrome display / with backlight(optional 128x64 dot matrix LCD / with backlight)
Enclosure material Aluminium alloy made single chamber or dual chamber( 220VAC is available for dual chamber only)
Cable connector M20x1.5 (⌀5...9mm)
IP rating IP67  (electronic compartment filled with silica gel)
Approval CNEX: Ex ia IIC T6 Ga 
Package size L x W x H 435mm x 275mm x 275mm
Application Liquid, Powder, Paste

Dimensions

 

Installing Applications

Applications

© Chinasimba 2004 - 2024
闽公网安备35010502000147号