Characteristics
■ 80GHz Frequency FMCW radar system.
■ Measurement application in liquids, solids, the nozzle diameter ≥100 mm.
■ Suitable for dust applications, also the liquid which be heated with steam.
■ Max. measuring range 80M
Specifications
ANL-9080N100 | Lens material PTFE | Lens material PEEK | N60 (cool version) |
---|---|---|---|
Max. measuring range | 80M | 80M | 80M |
Near blind spot | <100mm from the flange down surface | ||
Tx/Rx frequency | Tx/Rx frequency 76.2 to 80.2GHz Dynamic FM Sweep Bandwidth 1~4GHz (The adjustment FM range can be customized according to the ISM requirements of the customer’s region) |
||
Meas. Principle | FMCW Radar System | ||
Lens Antenna Medium | PTFE Φ100mm | PEEK Φ100mm | PEEK Φ100mm |
Antenna beam / Gain | Beam angle 3.5°/ Gain 31.51dB | Beam angle 3.5°/ Gain 31.4dB | |
Meas. Resolution | 0.1mm (<10m range) | ||
Meas. Accuracy | ±2 mm | ||
Ambient temperature | -40 … +85 °C | -60 … +105 °C | |
Process temperature | -40°C … +200°C | -60°C … +200°C | |
Process pressure | -0.2 ~ +0.5MPa | -1.0 ~ +3.5MPa | |
Process connection | Flanges ≥DN100 | ||
Signal output | 4-20 mA/HART7 2-wire, 4-20 mA/HART7 4-wire, Profibus PA / DP, Ethernet-APL, Modbus protocol 4-wire | ||
Variables influencing meas. accuracy |
Specifications for the digital measured value: Temperature drift - Digital output: ±1mm/10K relating to the max. measuring range or max. 15 mm Additional deviation through electromagnetic interference acc. to EN-61326: < ±10 mm Specifications apply also to the current output Temperature drift - Current output: ±0.01%/10K relating to the 16.7 mA span or max. ±0.15% Deviation in the current output due to digital/analogue conversion Non-Ex and Ex-ia version: < ±1μA; Ex-d-ia version: < ±1μA Additional deviation through electromagnetic interference acc. to EN-61326: < ±150μA |
||
Indication/Adjustment (LOI) |
1. 160x80 LCD FSTN RGB backlight monitor adapter with keyboard module, operation Temp. -20°C … 70°C. or 128x64 OLED monitor adapter with keyboard module, operation Temp. -55°C … 80°C. (option) or 230x240 LCD TFT colors monitor adapter with keyboard module, operation Temp. -20°C … 70°C. (option only for 4-wrie system) 2. (APP) Radar MobileManager via BT wireless connection 3. (PC software) Radar PCManager /or Via a PC with PACTware/DTM (an interface converter AiW-305 USB CONNECT is required) |
||
Power supply | 16V ~ 40 VDC / Load resistor > 600Ω | ||
Wireless communication | Bluetooth 5.0 (Bluetooth 4.0 LE compatible), communication range 40m, in rainy day 20m | ||
Approvals | Ex ia IIC T6 Ga IP67; Ex d IIC T6 Gb IP67 | ||
Housing | Single chamber / Double chamber, Aluminum / Stainless steel / Plastic PBT, IP66 / IP67 / IP68 | ||
Applications | liquids, solids, dust applications |
Dimensions
DTM Adapter
AiW-305 USB Converter Adapter
Remote programmer cum Indicator Adapters
Remote indicator with HART compatible (RDM-25)
Remote indicator via Serial communication (LRD-21)
Remote indicator via Bluetooth communication
ANL9080 radar level transmitters (with Bluetooth function) can be connected to mobile phone through Bluetooth wireless system.
The mobile phone needs to install the RadarMobileManager APP. This is a free registered APP (Android and IOS etc.) software, which
can be downloaded and installed directly in major APP Stores, or please contact the relevant product suppliers.
The Radar Antenna Specification of the ANL-9080N100 (Datasheet download)
Thermal simulation graph for the ANL-9080N100-2 (Datasheet download)
Aluminum housing
Stainless steel housing
Plastic housing
Indication/Adjustment LOI Adapter
Early Products
ANL9080-DN100 is a general-purpose 80GHz FM radar level transmitter suitable for solids 、 liquid level、powder、paste measurement application in small, medium and large measuring ranges (0.1m to 100m), featuring fast measurement response, 2-wire 4mA current start-up, and active tracking recognition technology with multi-echo mode software design, which makes it suitable for use in harsh environments. Under working conditions, it can steadily identify the correct echo position; in the stirred tank environment, rapid and frequent loading and unloading of industrial process reaction tank measurement applications, it shows the absolute superior performance. In solids measurement or large dust and heap angle environment, the product system will automatically open the return gain control function according to the quality of the return signal.
Applications: Petrochemical Industry, Pharmaceutical Industry, Coal Mine, Cement Production, Sintering, Food Industry and Grain Storage, Alluminium Oxide, Bulk Solids.
To order or inquire, please contact us
Radar Frequency | 76.2 to 80.2GHz dynamic FM sweep bandwidth 4GHz (On demand adjustment on the FM sweep bandwidth is available to comply with ISM requirements) |
Measuring Range |
40.0m / 100.0m |
Dead Band | 50mm |
Measuring Principle | FMCW Radar TE01 Mode |
Resolution | 0.1mm (40m Measuring Range) / 0.5mm (100m Measuring Range) |
Accuracy | ±3mm (40m Measuring Range) / ±5mm (100m Measuring Range) |
Antenna Material | PEEK material, Lensed Antenna |
Antenna Beam | 3°/ Antenna Gain 31.4dB |
Signal Outpu | 4-20mA, HART5 (standard configuration) /or HART7 |
Power Supply | 16V~36VDC / Two-wired |
Process Connection | DN100 flange, with air purge |
Process Temperature | ‐40 ~ 150℃, or ‐40 ~300℃ (Extra cooling fins are required ) |
Ambient Temperature | ‐40 ~ 85℃,≤95%RH |
Process Pressure | ‐1 ~ 3MPa or ‐4~10MPa (Extra reinforce members are required) |
Local Configurable | PC desktop software(Radar PCManger) / 4 on panel push buttons/ Smartphone app and Wechat Mini-program (RadarMobileManger) / Vessel Side Meter |
WIFI Connection | Bluetooth / LoRa / IOT |
Comm. Protocol | HART / MODBUS / PROFIBUS (optional) |
Fail Safe | 22mA or 4mA/20.5mA (configurable) |
Display | 160x80 dot matrix black and white monochrome display / with backlight(optional 128x64 dot matrix LCD / with backlight) |
Enclosure Material | Aluminium alloy made single chamber or dual chamber( 220VAC is available for dual chamber only) |
Cable Connector | M20x1.5 (⌀ 5...9mm) |
IP Rating | IP67 (electronic compartment filled with silica gel) |
Approval | CNEX: Ex ia IIC T6 Ga |
Package Size | L x W x H 435mm x 275mm x 275mm |
Application | Liquid, Solid, Powder, Paste |